PS-525 SPECIFICATIONS

Digital Altimeter:

Display Range – model PS-525: -1000 to 35,000 feet (-305 to 10,700 meters)

Display Range – model PS-525A: -1000 to 50,000 feet (-305 to 15,240 meters)

Vacuum Pump Range – model PS-525: -1000 to 35,000 feet (-305 to 10,700 meters)

Vacuum Pump Range – model PS-525A: -1000 to 50,000 feet (-305 to 15,240 meters)

Resolution: from -1500 to 20,000 feet resolution is in 1-foot increments

From 20,001 to 30,000 feet resolution is in 2-feet increments

From 30,005 to 50,000 feet resolution is in 5-feet increments

All metric resolution is in 1-meter increments

Sensor Accuracy: approximately 0.03 %

Temperature range: 32 degrees F to 125 degrees F (-1 C to 51 C) limited by LCD display

Altitude units: Feet or Meters

Other Measurement Units:

inHg (inches of mercury): 0.295 to 32.48 in increments of 0.01

mBar (milli bars): 10 – 1100 in increments of 0.1

PSIA (pounds/square inch): 0.145 to 15.95 in increments of 0.01

mm HG (millimeters of mercury): 7.5 – 825 in increments of 0.1

 

Digital Airspeed:

Range: 18 – 500 Knots, 34 – 920 KPH, or 21 – 575 MPH

Resolution: 1 MPH, 1 KPH, or 1 Knot

Sensor Accuracy: approximately 0.03%

Temperature range: 30 degrees F to 125 degrees F (-1 C to 51 C) limited by LCD display

Other Measurement Units:

inHg (inches of mercury): 0.295 to 32.48

mBar (milli bars): 10 – 1100

PSI (pounds/square inch) 0.145 to 15.95

mm HG (millimeters of mercury): 7.5 – 825

E.P.R. (engine pressure ratio): 0.07-6.00

 

Display Type: LCD Size: Altimeter and Airspeed: 99 x 24 mm Decoder display: 38 x 16 mm

Physical Dimensions: 10.5”D X 14.25”L X 10”H (27x35x25 cm)

Weight: approximately 20 lbs (9 Kg)

Power Source:

External: 24 VDC (from a 110/220 VAC adaptor)

Internal: 12/24 VDC (from internal rechargeable batteries)

Optional: 110/220 VAC Mains powered, without internal batteries

Current draw: Display only: 125 mA

370 mA with vacuum pumps operating

320 mA with pressure pump operating

540 mA with all systems operating (and no encoder attached)

Other Features:

Leak test feature: 2 minutes, selectable down to 30 seconds

VSI (vertical speed indicator)

Note: The PS-525 does NOT have the precision required to test RVSM altimeter systems.

 

Encoder Reader:

The Encoder Reader is compatible with outputs of the following altitude encoders:

ACK (gray code, 1200, 2400, 9600 baud)

Shadin (gray code, 9600 baud)

Trans-Cal (gray code, 1200, 2400, 9600 baud)

Ameri-King (gray code)

The Encoder Reader is compatible with the following RS-232 protocols:

Garmin 1200, 9600 baud

Northstar 2400 baud

Shadin 9600 baud

UPS AT, Apollo 1200 baud

Trimble 9600 baud

 

Previous Feature Next Feature